L-3 Communications Telemetry & Instrumentation
L-3 Communications Electrodynamics, Inc.L-3 Communications Electrodynamics, Inc.L-3 Communications Electrodynamics, Inc.L-3 Communications Electrodynamics, Inc.
Electrodynamics, Inc. HomeElectrodynamics, Inc. About UsElectrodynamics, Inc.  ProductsElectrodynamics, Inc.  News and EventsElectrodynamics, Inc.  CareersElectrodynamics, Inc.  Contact Us



   
 > PALM™ Compatible
Hours Meters and Event Counters
 > L-3 To Provide Crash Recorder For F-35 Joint Strike Fighter
 > Solid State FaultLite ™ LED Non-Volatile Fault Indicators
  > Solid State,PC Board Mount Elapsed Time Indicator
  > CI 25 Magnetic Latching Indicator
  > ML 1636 LED Status Indicator
  > ML 1638 Night Vision Compatible LED Fault Locating Indicator
  > Solid State, PC Board Mount Event Counter
  > CI 75 series large display status indicators
  > L-3/EDI Quality System is ISO 9000/AS9100 certified
Customer Information

SOLID STATE, PC BOARD MOUNT EVENT COUNTER
MONITORS YOUR SYSTEM USAGE

ROLLING MEADOWS, ILLINOIS, USA. L-3 Communications, Electrodynamics, Inc. announces the introduction of the DDS101 solid state Event Counter that has been developed to meet the most difficult requirements of many military and aerospace applications. The DDS101 features non-volatile memory and meets all of the requirements of MIL-M-7793/13. It provides a highly reliable means of monitoring systems' event activity. All connections are made via printed wiring board and the output brought to a data collection point for system reading or to a single dedicated connector. Events are read from the DDS101 counter by mating the printed wiring board connections with the M7793/12-1 reader's connector and operating the reader.

Event range is 99,999 events. The output is serial binary coded decimal format. The package measures 1.1" long x .450" wide x .275" high. Weight is less than 0.2 ounces.

Environmental Specifications include operating temperature range of -65 to +125°C meets shock testing per MIL-STD-202, Method 213, Cond. I; Vibration per MIL-STD-202, Method 204, Cond. D; and life accuracy of ± 0.1% from -65 to +125°C and 4.5 to 10 VDC.

DDS101 meters meet or exceed applicable requirements of MIL-M-7793/13. Operating Voltage Range is 4.5 to 10 VDC. Ripple Voltage is 2 volt peak (4 volt peak-to-peak) ripple between 10 Hz and 10 kHz superimposed on 7.0 VDC. Output impedance is ± 10%. Logic zero is between 0.0 and +0.2 volts. Logic one is between +3.3 and +6.6 volts. Power consumption is 2 milliwatts, max. Transient protection test subjects the DDS100 to ±25 volt transients of 10 microsecond duration occurring at a 1 millisecond repetition rate.

Delivery time is 4-6 weeks after receipt of order.

Click here for details on the DDS101 solid state event counter.

 